Electrosurgical Units
33
- Coated and insulated electrode
- Electrode tip partially insulated
- Does not cause skin lesions
- Total length of insulated shaft: 31 mm
- Available individually or as a set
- Bipolar forceps with European flat plug
- With angled tip
- Knurled finish for non-slip grip
- Tip in different sizes
- Autoclavable, can be reused
- Compatible with radiosurg 2200
- Automatically switches on the smoke evacuation system
- Protects the filter of the smoke evacuation system
- Cable length: 2.5 m
- Delivery contents: 1 cable
- Coated, bent ENT electrode
- Total length of needle: 18 mm
- With pointed needle
- Rigid shaft (not bendable)
- Total length of insulated shaft: 74 mm
- High quality cutting electrode
- Made of fine wire 0.25 mm
- With straight and bendable shaft
- Total length of insulated shaft: 35 mm
- For radioSURG® PT/PTA, TP/TPA & M
- With three different needle electrodes
- Conical needle and bendable shafts
- Needle diameter: 0.5 mm, 0.7 mm & 1.0 mm
- Needle length: 20 mm
- Total length of insulated shaft: 44 mm
- Professional monopolar unit
- For cutting and coagulation
- Enables pressureless, "cold" cuts
- Class IIb medical device
- Automatic switch-off after 1 min.
- Short and straight bipolar forceps
- For the radioSURG® 2200 PTA, TPA and B
- Tip width: 0.6 mm
- Including bipolar cable (3m)
- Autoclavable
- No adhesion of organic tissue
- Secure grip thanks to grooves
- With Euro flat connector
- For all radioSURG® 2200 RF units
- Available in various versions
- With cutting and coagulation electrodes
- All shafts can be bent as required
- Sterilisable and reusable
- For radioSURG® PT/PTA, TP/TPA and M
- Delivery contents: 1 set with 7 electrodes
- Made of 0.25 mm thick fine wire
- Side length: 8 mm
- Straight shaft can be bent if required
- Total length of insulated shaft: 31 mm
- Delivery contents: 2 pieces
- For radioSURG® 2200 TP/TPA, PT/PTA, B and M
- For connection of various electrodes
- Colour coded, autoclavable & reusable
- Available for incision or coagulation
- Including 2.5 m long connection cable
- Sterile coagulation & cutting electrodes
- Total length of insulated shaft: 33.5 mm
- Hygienic disposable article
- For radioSURG® 2200 TP/TPA, PT/PTA and M
- Available in various versions
- 4-stage high-performance filter
- For the smokeSTAR smoke evacuator
- Filters large particles, aerosols, gases & odours
- With a filter efficiency of 99.999 %
- Long runtime of up to 35 h
- Automatic remote control
- Ffor the smokeSTAR smoke evacuation system
- With 3.05 m connection cable
- Facilitates work in the operating theatre
- Particularly high-quality workmanship
- For self-adhesive disposable neutral electrodes
- Connector to unit & clamp connection for electrode
- For radioSURG® PT/PTA, TP/TPA, B and M
- Particularly high-quality and robust workmanship
- Total length of the cable: 3.0 m
- Sterile single-use bipolar forceps
- With 3 m permanently attached cable
- Compatible with radioSURG® 2200
- Various lengths & tip widths
- Maximum output voltage: 500 Vp
- Minimise the risk of cross-contamination
- For bipolar forceps with Euro flat plug
- Suitable for radioSURG® 2200 PTA, TPA & B
- Autoclavable and reusable
- Length of cable: 2.5 metres
- Delivery contents: 1 piece
- Particularly thin disc
- Total length of insulated shaft: 31 mm
- For the radioSURG® 2200 TP/TPA, PT/PTA & M
- Available in various sizes
- Delivery contents: 2 pieces
High-Frequency Surgery in the Dental Practice
HF surgery devices operate with high-frequency alternating current and utilize the thermal effect generated in the tissue. Electrical energy is converted into heat energy, using frequencies between 300 kHz and 4 MHz. The form and intensity of the chosen current must be adapted to the type of tissue being operated on. In principle, the lowest possible frequency for the tissue should always be selected. This energy or current is used for cutting, coagulating, or for combined applications.