Skip to main content Skip to search Skip to main navigation
Register
Help and Contact
FAQs and Shipping Information Guaranteed Usable Until Date 5% Discount for PD Plus Customers Payment Options
FAQs and Shipping Information

Learn more
Guaranteed Usable Until Date

Learn more
5% Discount for PD Plus Customers

Learn more
Payment Options

Learn more

Re-Order in a Flash - Just Log In

If you’ve ordered from us before, you can repeat your last order with a single click. Log in to enjoy a faster checkout, personalised recommendations, and access to your order history.

CH EN
CHF

Electrosurgery

53

53 products

Filter & sorting
More filters Less filters
Titanium patient eyewear with adjustable nose bridge and headband
Laservision
Titanium Patient Eyewear
Art. no.: 144171

Average rating of 0 out of 5 stars

0
  • Adjustable nose bridge and head band
  • High wearing comfort thanks to silicone rings
  • Sterilisable, nickel-free and paramagnetic
  • Protection levels from 180 nm to 25000 nm
  • Including soft case and 2 pairs of silicone replacement rings
CHF 274.49 net
Your PLUS customer savings CHF 13.72 net
In stock
Packaging unit: 1 PC
radioSURG® 2200 TPA radiosurgical unit for human, dental and veterinary medicine
Meyer-Haake
radioSURG® 2200 TPA
Art. no.: 147687

Average rating of 0 out of 5 stars

0
  • Constant voltage for a clean cut
  • Suitable for cutting and coagulation
  • No necrosis, discolouration or trauma
  • Integrated automatic switch-off
  • Memory of the last used settings
CHF 10,494.29 net
Your PLUS customer savings CHF 524.71 net
Item is currently being restocked Your order will be dispatched as quickly as possible
radioSURG® fine wire needle electrode optionally available individually or as a set
Meyer-Haake
radioSURG® Fine Wire Needle Electrode
Art. no.: EX-147717

Average rating of 0 out of 5 stars

0
  • Coated and insulated electrode
  • Electrode tip partially insulated
  • Does not cause skin lesions
  • Total length of insulated shaft: 31 mm
  • Available individually or as a set
From CHF 97.79 net
Your PLUS customer savings CHF 4.89 net
In stock
3 variants available More
Please select a variant first.
Professional radioSURG® 2200 PTA radiosurgical unit for human and veterinary medicine
Meyer-Haake
radioSURG® 2200 PTA
Art. no.: 147686

Average rating of 0 out of 5 stars

0
  • Incision and coagulation for surgical procedures
  • Faster & gentler than kilohertz devices
  • No necrosis, discolouration or tissue trauma
  • Electric current with a frequency of 2.2 MHz
  • 45 surgical settings pre-programmed from 8 specialties
CHF 16,144.29 net
Your PLUS customer savings CHF 807.21 net
In stock
radioSURG® bipolar forceps (angled) with tip available in different sizes
Meyer-Haake
radioSURG® Bipolar Forceps (angled)
Art. no.: EX-147729

Average rating of 0 out of 5 stars

0
  • Bipolar forceps with European flat plug
  • With angled tip
  • Knurled finish for non-slip grip
  • Tip in different sizes
  • Autoclavable, can be reused
From CHF 264.29 net
Your PLUS customer savings CHF 13.21 net
In stock
2 variants available More
Please select a variant first.
radioSURG® 2200 PT/PTA foot pedal including 3m long cable
Meyer-Haake
radioSURG® 2200 PT/PTA Foot Pedal
Art. no.: 147698

Average rating of 0 out of 5 stars

0
  • Accessories for radioSURG® 2200 PT or PTA
  • Not autoclavable
  • Including 3m long cable
  • Facilitates work in the operating theatre
  • Easy to clean
CHF 1,149.79 net
Your PLUS customer savings CHF 57.49 net
Item is currently being restocked Your order will be dispatched as quickly as possible
Packaging unit: 1 PC
smokeSTAR trigger cable for automatic connection of the smokeSTAR smoke evacuation system
Meyer-Haake
smokeSTAR Trigger Cable
Art. no.: 147743

Average rating of 0 out of 5 stars

0
  • Compatible with radiosurg 2200
  • Automatically switches on the smoke evacuation system
  • Protects the filter of the smoke evacuation system
  • Cable length: 2.5 m
  • Delivery contents: 1 cable
CHF 77.99 net
Your PLUS customer savings CHF 3.90 net
In stock
Packaging unit: 1 PC
radioSURG® ENT needle electrode no. 36 for radioSURG® 2200 TP/TPA, PT/PTA & M units
Meyer-Haake
radioSURG® ENT Needle Electrode No. 36
Art. no.: 147713

Average rating of 0 out of 5 stars

0
  • Coated, bent ENT electrode
  • Total length of needle: 18 mm
  • With pointed needle
  • Rigid shaft (not bendable)
  • Total length of insulated shaft: 74 mm
CHF 73.99 net
Your PLUS customer savings CHF 3.70 net
In stock
Packaging unit: 1 PC
radioSURG® blade electrode for cutting, coagulation and preparation
Meyer-Haake
radioSURG® Blade Electrode
Art. no.: EX-147706

Average rating of 0 out of 5 stars

0
  • Extra thin blade for precise work
  • With rigid shaft (not flexible)
  • For radioSURG® TP/TPA, PT/PTA and M
  • Available in short or long version
  • Delivery contents: 1 piece
From CHF 73.99 net
Your PLUS customer savings CHF 3.70 net
In stock
2 variants available More
Please select a variant first.
radioSURG® sclerotherapy electrode available in various versions
Meyer-Haake
radioSURG® Sclerotherapy Electrode
Art. no.: EX-147719

Average rating of 0 out of 5 stars

0
  • Uncoated fine wire electrode
  • Can be used for various indications
  • With rigid shaft (not bendable)
  • Total length of insulated shaft: 31 mm
  • Available in different versions or as a set
From CHF 97.79 net
Your PLUS customer savings CHF 4.89 net
In stock
4 variants available More
Please select a variant first.
radioSURG® needle electrode no. 6 for the radioSURG® PT/PTA, TP/TPA and M
Meyer-Haake
radioSURG® Needle Electrode No. 6
Art. no.: 147705

Average rating of 0 out of 5 stars

0
  • High quality cutting electrode
  • Made of fine wire 0.25 mm
  • With straight and bendable shaft
  • Total length of insulated shaft: 35 mm
  • For radioSURG® PT/PTA, TP/TPA & M
CHF 97.79 net
Your PLUS customer savings CHF 4.89 net
In stock
Packaging unit: 2 PC
radioSURG® needle electrode set ideal for fat preparation
Meyer-Haake
radioSURG® Needle Electrode Set
Art. no.: 147727

Average rating of 0 out of 5 stars

0
  • With three different needle electrodes
  • Conical needle and bendable shafts
  • Needle diameter: 0.5 mm, 0.7 mm & 1.0 mm
  • Needle length: 20 mm
  • Total length of insulated shaft: 44 mm
CHF 149.99 net
Your PLUS customer savings CHF 7.50 net
In stock
Packaging unit: 3 part
Suitable and extensive accessories for every need available separately
Meyer-Haake
radioSURG® 2200 M
Art. no.: 147688

Average rating of 0 out of 5 stars

0
  • Professional monopolar unit
  • For cutting and coagulation
  • Enables pressureless, "cold" cuts
  • Class IIb medical device
  • Automatic switch-off after 1 min.
CHF 7,099.99 net
Your PLUS customer savings CHF 355.00 net
In stock
radioSURG® standard bipolar forceps for gentle, bipolar coagulation
Meyer-Haake
radioSURG® Standard Bipolar Forceps
Art. no.: 147694

Average rating of 0 out of 5 stars

0
  • Short and straight bipolar forceps
  • For the radioSURG® 2200 PTA, TPA and B
  • Tip width: 0.6 mm
  • Including bipolar cable (3m)
  • Autoclavable
CHF 264.29 net
Your PLUS customer savings CHF 13.21 net
In stock
Packaging unit: 1 PC
radioSURG® non-stick bipolar forceps prevent bio-tissue adhesion
Meyer-Haake
radioSURG® Non-Stick Bipolar Forceps
Art. no.: EX-147732

Average rating of 0 out of 5 stars

0
  • No adhesion of organic tissue
  • Secure grip thanks to grooves
  • With Euro flat connector
  • For all radioSURG® 2200 RF units
  • Available in various versions
From CHF 479.29 net
Your PLUS customer savings CHF 23.96 net
In stock
3 variants available More
Please select a variant first.
MD 100 Electrosurgical Unit
MicroMed
MD 100 Electrosurgical Unit
Art. no.: 150693
EAN: 4064468033150

Average rating of 0 out of 5 stars

0
  • Compact electrosurgical device with 100 watts output power
  • Monopolar and bipolar cutting and coagulation functions
  • Automatic power control for consistent results and high patient safety
  • Nine individually programmable memory slots for frequently used settings
  • Intuitive operation and flexible activation via handpiece or footswitch
  • Compatible with a wide range of instruments and accessories
CHF 2,694.29 net
Your PLUS customer savings CHF 134.71 net
In stock
Packaging unit: 1 PC
Dermatology accessory set for the MD I HF device
MicroMed
Dermatology Accessory Set for the MD I HF Device
Art. no.: 136276

Average rating of 0 out of 5 stars

0
  • Electrosurgical accessory set
  • Contains needle, wire and disk electrodes + more
  • For treating many skin diseases
  • MicroPen electrode handle with a button
  • Rubber band with holes
CHF 554.79 net
Your PLUS customer savings CHF 27.74 net
In stock
radioSURG® Standard Electrode Set no. 300 consisting of 7 different cutting & coagulation electrodes
Meyer-Haake
radioSURG® Standard Electrode Set No. 300
Art. no.: 147693

Average rating of 0 out of 5 stars

0
  • With cutting and coagulation electrodes
  • All shafts can be bent as required
  • Sterilisable and reusable
  • For radioSURG® PT/PTA, TP/TPA and M
  • Delivery contents: 1 set with 7 electrodes
CHF 294.99 net
Your PLUS customer savings CHF 14.75 net
In stock
Packaging unit: 7 part
Professional and powerful smokeSTAR smoke evacuator (articulated armstand not included)
Meyer-Haake
smokeSTAR
Art. no.: 147685

Average rating of 0 out of 5 stars

0
  • Surgical smoke evacuation
  • Efficient 4-fold filter with a lifetime of 35 h
  • Protects against toxic compounds
  • Minimises unpleasant odours
  • Particularly quiet operation
CHF 5,594.49 net
Your PLUS customer savings CHF 279.72 net
In stock
Needle electrode suitable for HF units MD I, MD 3 & MD 100
MicroMed
Needle Electrode
Art. no.: 147390

Average rating of 0 out of 5 stars

0
  • Diameter: 0.2 mm
  • 45° angled
  • Figure 2
  • Sterilisable at 134 °C
  • 1 needle electrode
CHF 14.29 net
Your PLUS customer savings CHF 0.71 net
In stock

Electrosurgical Devices for Cutting and Coagulating Tissue

Electrosurgical units (ESU), also known as diathermy machines or high-frequency surgery units, utilise the effect that high-frequency alternating current has on the tissue. High-frequency surgery usually uses frequencies between 300 kHz and 4 MHz, as currents in this frequency range create a thermal effect in the tissue that can be used in medicine for cutting and coagulation. The thermal effect is caused by the conversion of electrical energy into thermal energy.

To efficiently use this effect, the electrosurgical unit is connected to special electrosurgical electrodes. Depending on the type of application, these electrodes differ in shape and size. A distinction can be made, for example, between ball electrodes, needle electrodes and loop electrodes.

Cutting with Electrosurgery Units

The cutting of tissue with a surgical diathermy machine is based on the rapid heating of the tissue fluid and the resulting explosive vapour pressure, which causes the cell walls and the tissue to tear apart. Cutting with an electrosurgical device offers many advantages; it prevents bleeding and germ transfer, and the tissue is mechanically protected.

Coagulation with the Diathermy Machine

During coagulation, tissue is boiled away, so to speak. The slow heating causes the tissue to shrink and the existing tissue fluid to thicken or evaporate. This effect comes in handy when closing smaller vessels during surgical procedures and is particularly effective when treating spider veins and haemangiomas.

Monopolar Technique

The monopolar technique requires two electrodes: a large neutral electrode and an active electrode with a very small contact area. The current flows through the active electrode into the body, creating the desired thermal effect at the target site. The large neutral electrode returns the current from the patient without causing burns due to its low current density.

Bipolar Technique

The bipolar technique does not require a separate neutral electrode. In this method, the instrument connected to the electrosurgical unit combines the active and neutral electrodes. For example, in a bipolar forceps, one arm acts as the active electrode and the other as the neutral electrode. The current thus flows only within the treated tissue, offering precise control. This technique is especially preferred for delicate neurological procedures.

Difference Between Cauteries and Electrosurgical Units

Unlike an electrosurgical unit, where alternating current generates heat in the tissue through electrical resistance, a cautery is directly heated using direct current. The heat is transferred to the tissue via the cautery tip, and no current passes through the tissue. This technique is now only used when any current flow through the body must be avoided.

Order Electrosurgical Units from Praxisdienst

At Praxisdienst, you will find various electrosurgical units suitable for bipolar and/or monopolar procedures. We also offer accessory kits for different medical specialties, such as surgery or dermatology, which include HF electrodes, handpieces, cables, and other components. The electrosurgical units available from us are easy to handle and versatile in use.

We offer both single-use and reusable medical instruments, along with other operating theatre supplies, in the overview of our Instruments category.

If you have questions about our electrosurgical units or wish to reorder individual accessories, such as a bipolar forceps, our customer service team will be happy to assist. You can contact us by phone, live chat, or email.